Description
BeyoFast™ SYBR Green qPCR Mix (2X) is a high-quality supermix for real-time PCR. It is mainly used in gene expression studies and genomics applications, with high specificity and sensitivity.
SYBR Green I contained in the BeyoFast™ SYBR Green qPCR Mix (2X) is a dye with green fluorescence that binds into the minor groove of dsDNA. It has very weak fluorescence in the free state, but when binding to dsDNA, its fluorescence is increased significantly. During PCR, as the target sequence is amplified, SYBR Green I binds to each new copy of dsDNA during the extension step, by which the amount of dsDNA generated by PCR amplification can be quantified by measuring the fluorescence intensity.
BeyoFast™ SYBR Green qPCR Mix (2X) contains BeyoFast™ Taq DNA Polymerase and its monoclonal antibody that binds with DNA polymerase and inhibits its activity at room temperature, allowing reactions to be set up at room temperature. During the initial DNA denaturation step (reaction temperature ~94°C), the antibody is denatured, releasing the polymerase and allowing DNA synthesis to proceed. The use of a hot-start DNA polymerase prevents nonspecific amplification due to mispriming and/or the formation of primer dimers during PCR assembly at lower temperatures, thus greatly improving the specificity, sensitivity and accuracy of qPCR reactions.
BeyoFast™ SYBR Green qPCR Mix (2X) is a 2X concentrated solution of Taq DNA Polymerase, dNTPs, SYBR Green I, and all of the components required for PCR, except DNA template and primers.
This product does not contain ROX fluorescent dye and can be used on qPCR instrument that does not require ROX as a reference dye. ROX is usually used as a passive reference fluorescent dye in qPCR for signal normalization. ROX is not essential for qPCR, however, adding it can help reduce variations of fluorescent values in samples induced by pipetting errors, sample evaporation, or other technical problems. The optimal ROX concentration in qPCR reaction is dependent on the type of qPCR instrument. Based on the type of qPCR instrument available, choose High ROX, Low ROX or ROX-free qPCR mix. The BeyoFast™ SYBR Green qPCR Mix (2X, High ROX) can also be used on qPCR instruments requiring no or low concentrations of ROX. Refer to the following table for qPCR instruments with different requirements of ROX.
| ROX Requirement | Real-time PCR Instrument |
| No Requirement |
Bio-Rad: CFX384, CFX96, MiniOpticon, iCycler IQ, MyiQ and iQ5;
Eppendorf: Mastercycler ep realplex and realplex2 s;
Qiagen/Corbett Rotor-Gene: 6000;
Roche: LightCycler 480; Cepheid: SmartCycler; Illumina: Eco qPCR
|
| Low ROX |
ABI: 7500(Fast), ViiA 7, QuantStudio 6 and 7 Flex Systems;
Stratagene: Mx3000P, Mx3005P and Mx4000;
Qiagen/Corbett Rotor-Gene: 3000;
Bio-Rad/MJ: Chromo4, Opticon 2 and Opticon;
|
| High ROX |
ABI GeneAmp 5700; ABI PRISM 7000, 7700; ABI 7300, 7900HT(Fast);
ABI StepOne(Plus)
|
| Item | Component | Quantity |
| D1047-5ml | BeyoFast™ SYBR Green qPCR Mix (2X) | 1ml×5 |
| Manual | – | 1 copy |
Store at -20℃ for up to one year, or 4ºC for up to one month. Avoid repeated freeze-thaws. The reagent is light-sensitive and should be protected from light.
Thaw the qPCR Mix completely prior to use. Mix well gently by inversion to avoid the production of bubbles.
When the annealing temperature of primers is lower than 60℃, we recommend using the three-step method for PCR amplification.
Avoid strong light during the preparation of qPCR reactions, as the fluorescence of SYBR Green I dye quenches under strong light.
Increase the extension time to 60 s or use a three-step method for PCR amplification of DNA fragments longer than 350bp or with high GC content to improve the amplification efficiency.
Although repeated freeze-thaws up to 10 times do not cause any obvious change in the performance of the qPCR Mix, it should still be avoided. Too many times of repeated freezing and thawing may decrease the activity of the mix.
Because PCR is a powerful technique capable of amplifying trace amounts of DNA, all appropriate precautions should be taken to avoid cross-contamination. Discard PCR products after sealing to avoid their contamination of experimental surroundings.
This product is for R&D only. Not for drug, household, or other uses.
For your safety and health, please wear a lab coat and disposable gloves during the operation.