Currency

BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX)

€ 138,00

BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX) is a high-quality supermix for real-time PCR. It is mainly used in gene expression studies and genomics applications, with high specificity and sensitivity.

Package: 5ml

Description

BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX) is a high-quality supermix for real-time PCR. It is mainly used in gene expression studies and genomics applications, with high specificity and sensitivity.

SYBR Green I contained in the BeyoFast™ SYBR Green qPCR Mix (2X) is a dye with green fluorescence that binds into the minor groove of dsDNA. It has very weak fluorescence in the free state, but when binding to dsDNA, its fluorescence is increased significantly. During PCR, as the target sequence is amplified, SYBR Green I binds to each new copy of dsDNA during the extension step, by which the amount of dsDNA generated by PCR amplification can be quantified by measuring the fluorescence intensity.

BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX) contains BeyoFast™ Taq DNA Polymerase and its monoclonal antibody that binds with DNA polymerase and inhibits its activity at room temperature, allowing reactions to be set up at room temperature.  During the initial DNA denaturation step (reaction temperature ~94°C), the antibody is denatured, releasing the polymerase and allowing DNA synthesis to proceed. The use of a hot-start DNA polymerase prevents nonspecific amplification due to mispriming and/or the formation of primer dimers during PCR assembly at lower temperatures, thus greatly improving the specificity, sensitivity and accuracy of qPCR reactions.

BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX) is a 2X concentrated solution of Taq DNA Polymerase, dNTPs, SYBR Green I, and all of the components required for PCR, except DNA template and primers.

This product contains a low concentration of ROX fluorescent dye and can be used on the qPCR instrument that requires a low concentration of ROX as a reference dye. ROX is usually used as a passive reference fluorescent dye in qPCR for signal normalization. ROX is not essential for qPCR, however, adding it can help reduce variations of fluorescent values in samples induced by pipetting errors, sample evaporation, or other technical problems. The optimal ROX concentration in qPCR reaction is dependent on the type of qPCR instrument. Based on the type of qPCR instrument available, choose High ROX, Low ROX or ROX-free qPCR mix. The BeyoFast™ SYBR Green qPCR Mix (2X, High ROX) can also be used on qPCR instruments requiring no or low concentration of ROX. Refer to the following table for qPCR instruments with different requirements for ROX.

ROX Requirement Real-time PCR Instrument
No Requirement
Bio-Rad: CFX384, CFX96, MiniOpticon, iCycler IQ, MyiQ and iQ5;
Eppendorf: Mastercycler ep realplex and realplex2 s;
Qiagen/Corbett Rotor-Gene: 6000;
Roche: LightCycler 480; Cepheid: SmartCycler; Illumina: Eco qPCR
Low ROX
ABI: 7500(Fast), ViiA 7, QuantStudio 6 and 7 Flex Systems;
Stratagene: Mx3000P,  Mx3005P and Mx4000;
Qiagen/Corbett Rotor-Gene: 3000;
Bio-Rad/MJ: Chromo4, Opticon 2 and Opticon;
High ROX
ABI GeneAmp 5700; ABI PRISM 7000, 7700; ABI 7300, 7900HT(Fast);
ABI StepOne(Plus)

 

Packing List:
Item Component Quantity
D7262-5ml BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX) 1ml×5
Manual – 1 copy

 

Storage Conditions:

Store at -20℃ for up to one year, at 4ºC for up to one month. Avoid repeated freeze-thaws. The reagent is light sensitive and should be protected from light.

Precautions:

Thaw the qPCR Mix completely prior to use. Mix well gently by inversion to avoid the production of bubbles.

When the annealing temperature of primers is lower than 60ºC, we recommend using the three-step method for PCR amplification.

Avoid strong light during the preparation of qPCR reactions, as the fluorescence of SYBR Green I dye quenches under strong light.

Increase the extension time to 60 seconds or use a three-step method for PCR amplification of DNA fragments longer than 350bp or with high GC content to improve the amplification efficiency.

Although repeated freeze-thaws up to 10 times do not cause any obvious change in the performance of the qPCR Mix, it should still be avoided. Too many times of repeated freezing and thawing may decrease the activity of the mix.

Because PCR is a powerful technique capable of amplifying trace amounts of DNA, all appropriate precautions should be taken to avoid cross-contamination. Discard PCR products after sealing to avoid their contamination of experimental surroundings.

This product is for R&D only. Not for drug, household, or other uses.

For your safety and health, please wear a lab coat and disposable gloves during the operation.

Additional information

Weight 1 kg
Dimensions 30 × 30 × 20 cm

Instruction

Instructions for Use:

1. Set up qPCR reactions:
a. Thaw and mix well the BeyoFast™ SYBR Green qPCR Mix (2X). Once melted, keep it on ice.
b. Assemble qPCR reactions on ice as follows (e.g., in a 96-well plate):

Component Volume (µl)
BeyoFast™ SYBR Green qPCR Mix (2X, Low ROX) 10
Forward and Reverse Primer Mix (3μM each) 2
Template DNA 2
RNase-free Water 6
Total Volume 20

Note 1: Primer at a final concentration of 0.2-0.5μM normally works well, but primer concentration can be optimized between 0.1-1.0 μM.
Note 2: Add 1-10ng cDNA or 10-100ng genomic DNA in 20 µl of qPCR reaction as a starting point. When necessary, the DNA templates can be diluted in a gradient manner to determine the optimal amount of DNA template for qPCR reaction. When the cDNA obtained by RT-PCR reaction is directly used as the template, the addition amount should not exceed 10% of the total volume of PCR reaction.
Note 3: A reaction volume of 20µl is recommended for each well of a 96-well plate, which can be adjusted as needed.
Note 4: Negative control without DNA template is always recommended.
c. Mix well reactions by gentle vortex or pipetting. Centrifuge briefly to collect the liquid at the bottom of the PCR tube.
2. Transfer qPCR reactions to a qPCR instrument and run thermocycling conditions as follows:

Step Temperature Duration Cycles
Initial Denaturation 95℃ 2 min 1
Denaturation 95℃ 15 sec 40
Annealing and Extension 60℃ 15-30 sec
Melting Curve (optional) 95℃ 15 sec 1
60℃ 15 sec
95℃ 15 sec

Note 1: The PCR running conditions listed above are for general use only. They can be adjusted based on the template, primer sequence, the length of PCR product or GC content, etc.
Note 2: The duration for initial denaturation is usually 2 min, but can be adjusted to 5 min for the amplification of complex or GC-rich DNA fragments.
Note 3: The BeyoFast™ Taq DNA Polymerase is capable of amplifying at least 300bp in 15 seconds. For amplicons longer than 350bp or with high GC content, it is recommended to increase the extension time to 60 s or to use a three-step method to improve amplification efficiency.
Note 4: When the annealing temperature of primers is lower than 60ºC, we recommend using the three-step method for PCR amplification.
3. qPCR data analysis using the software provided in the qPCR instrument.
FAQ:
1. Nonspecificity or low amplification efficiency.
a. Primer sequence is not well designed. Use primer design tools for primer design to avoid inappropriate GC content, secondary structure, dimer, annealing temperature, length, specificity and other possible problems. Use primers published in the literature or order the tested qPCR primers.
b. The targeted DNA fragments may have a high GC content. It is difficult to amplify DNA fragments with high GC content. Redesign primers at a different region of the DNA target.
c. Preparation of PCR reaction mixture at room temperature results in nonspecific amplification easily, which can be prevented by using the hot-start DNA polymerase. To amplify DNA fragment which is hard to be amplified, assembling the PCR reaction mixture on ice can further reduce the nonspecific amplification.
d. Annealing temperature needs to be optimized or redesign primers.
e. The denaturation is insufficient for DNA amplicons with high GC content or longer length. In this case, redesign primers on regions easier to be amplified.
f. The amount of DNA templates is too low. Add more DNA templates.
g. DNA templates contain substances that inhibit PCR reactions and can be purified using appropriate DNA purification methods such as column purification.
2. Optimization of PCR conditions.
a. Primers at a final concentration of 0.2-0.5μM normally work well, but primer concentration can be adjusted between 0.1-1.0 μM. Reduce primer concentration to improve the specificity of PCR amplification and increase primer concentration to improve the amplification efficiency.
b. Annealing temperature: Two-step PCR amplification is regularly used with annealing and extension temperature at 60ºC. The annealing/extension temperature can be adjusted in the range of 60-64ºC. The specificity of qPCR reactions can be improved by increasing the annealing temperature appropriately. When the Tm value of primers is low, three-step PCR amplification can be tried. The annealing temperature of the three-step method is recommended to be between 56-64ºC.
c. Extension time: Two-step PCR amplification is recommended with an extension time between 15-30 seconds. For amplicons longer than 350bp or with high GC content, it is recommended to increase the extension time to 60 s or to use a three-step amplification method to improve amplification efficiency.

Product files

MSDS

https://scandicbiotech.com/wp-content/uploads/2026/04/D7262-1048.pdf

References

Related papers:

1. Yingchao Cui, Jingfeng Gao, Da Zhang, Yifan Zhao, Yuwei Wang
.
BIORESOURCE TECHNOL. 2020 Nov;315:123860. doi: 10.1016/j.biortech.2020.123860. (IF 7.539)
2. Shaoyuan Yang, Hairun Pei, Xiaoying Zhang, Qiang Wei, Jia Zhu, Jimin Zheng, Zongchao Jia
.
Open Biol. 2016 Jul;6(7):160082. doi: 10.1098/rsob.160082. (IF 4.931)
4. Shi Q, Zhao L, Xu C, Zhang L, Zhao H
.
Molecules. 2019 May 7 24(9). pii: E1766. (IF 3.267)
5. Jing Jing Fu, Xiao Hui Lv, Lin Xiang Wang, Xiu He, Yuan Li, Ling Yu, Chang Ming Li
.
Cell Mol Bioeng. 2020 Oct 27;14(2):187-199. doi: 10.1007/s12195-020-00660-x. (IF 1.72)
6. Jianbo He, Hongjuan Fu, Cancan Li, Zhihui Deng, Hui Chang
.
Phytomedicine. 2022 Jul 20:102:154159. doi: 10.1016/j.phymed.2022.154159. (IF 4.268)
7. Jiong Jiang, Yan Cheng, Shejiao Dai, Baicang Zou, Xiaoyan Guo
.
Environ Toxicol. 2022 Aug;37(8):1944-1956. doi: 10.1002/tox.23541. (IF 3.118)
8. Xueyan Wang, Chengwei Duan, Yu Li, Hongjian Lu, Kongwei Guo, Xin Ge, Tianpeng Chen, Yanxing Shang, Hongbin Liu, Dongmei Zhang
.
Int Immunopharmacol. 2022 Oct:111:109083. doi: 10.1016/j.intimp.2022.109083. (IF 3.943)

Related products

  • Actin Mouse Monoclonal Antibody

    This product is a β-actin mouse monoclonal antibody prepared using a synthetic peptide of N-terminal β-actin as antigen. The clone number is AC-74. This Actin antibody recognizes only β-actin in Western blot or immunostaining analysis. Package: 40T

  • Actin-Tracker Red-555

    Actin-Tracker Red-555 is a red fluorescent probe that specifically binds and labels filamentous actin (F-actin) in cultured cells or tissue sections. Package: 0.2ml

  • Akt Rabbit Polyclonal Antibody

    This product is a high-purity polyclonal antibody obtained by immunizing rabbit with a synthetic mouse Akt C-terminal segment with appropriate modifications and then purified in two steps using protein A and antigen peptide affinity chromatography. Package:10T, 10ul

  • Alexa Fluor 488-labeled Goat Anti-Rabbit IgG(H+L)

    AF488-labeled Goat Anti-Rabbit IgG (H+L) is a secondary antibody for immunofluorescence staining. Alexa Fluor (AF) dyes, trademarked by Molecular Probes, are advanced fluorescent dyes derived from Coumarin, Rhodamine, Xanthene, and Cyanine via sulfonation and chemical modification (e.g., Alexa Fluor 488, or AF488). Package: 100ul

  • Alexa Fluor 555-labeled Donkey Anti-Mouse IgG(H+L)

    AF555-labeled Donkey Anti-Mouse IgG (H+L) is a secondary antibody for immunofluorescence staining. Package: 100ul

Please enter your email address to receive your cart as a PDF.